Quantification of Heavy Metals and Other Inorganic Contaminants on the Productivity of Microalgae
Published on: July 10, 2015
[Determination of trace Hg element in gas by CVAAS with single optical path]
Shuai Wang1, Peng Wang, Xi-He Wang
1College of Energy Science and Engineering, Harbin Engineering University, Harbin 150001, China. wangshuai519@163.com
Abstract:
Since the anthropogenic emissions of mercury into environment were mostly entering the atmosphere through flue gas, continuous monitoring of mercury in the flue gas was significant for mercury emission control. A bench scale test rig was set up for the measurement of mercury through both wet chemical method and CVAAS (cold vapor atomic absorption spectrometry) with single optical path. The concentration of Hg in absorbent solution was determined by Hydra AA mercury analyzer. The concentration of Hg in gas was calculated in terms of wet chemical testing results, which showed a stable rate of permeation device. Hg atom absorption signal intensity was detected and analyzed in comparison with the test results of wet chemical methods according to Beer-Lambert law. Experimental data well agreed with the theory analysis, which indicated that the single optical path was suitable for the determination of trace Hg element in pure gas. Further research work should aim at the improvement of system adaptability and anti-jamming ability. To reduce the intensity fluctuation of mercury lamp, another spectral line could be detected simultaneously. Interference from surroundings, e.g. dust in gas or spot on the quartz surface, could be eliminated by optoelectronic coupling.
More Related Videos
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...