In Vitro Evaluation of The Effects Of Er,Cr:YSGG and Diode Lasers Used on Titanium Cylinder
Published on: June 6, 2025
Effect of Er:YAG laser on dentin bonding durability under simulated pulpal pressure
Ahmed Samir Bakry1, Masatoshi Nakajima, Masayuki Otsuki
1Cariology and Operative Dentistry Department, Graduate School, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, Japan. drahmedbakry@gmail.com
Purpose:
To evaluate the effects of Er:YAG laser ablation on the microtensile bond strength and the nanoleakage of Er:YAG-lased dentin bonded to a self-etching adhesive system with and without pulpal pressure.
Materials And Methods:
Twenty flat dentin surfaces were obtained from extracted molars. Ten specimens were irradiated by Er:YAG laser, other specimens (control group) were ground using #600 SiC paper. Direct communication to the pulp chamber was created by cutting at a level approximately 1 mm below the cementoenamel junction and parallel to the occlusal surface. The experimental groups were exposed to a simulated pulpal pressure of 15 cm H2O. Each specimen was restored using an adhesive and a photocured composite. The specimens were then sectioned vertically to obtain dentin/adhesive slabs. Ninety-six slabs were prepared for microtensile bond testing. Sixty-four slabs were immersed in ammoniacal silver nitrate tracer solution for 18 h, then rinsed thoroughly, and immersed in photodeveloping solution for 6 h prior to their examination by FE-SEM.
Results:
The method of dentin preparation and the pulpal pressure storage condition significantly affected the microTBS, while the storage duration did not (p < 0.05). The nanoleakage patterns observed in the dentin/bond interface differed depending on whether the dentin was conventionally prepared or ablated by Er:YAG laser.
Conclusion:
Er:YAG laser ablation to dentin adversely affected the microTBS and the sealing ability of SE Bond bonded to dentin under simulated pulpal condition.