Transesophageal Doppler devices: A technical review
Related Experiment Video
Updated: Jun 19, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Patrick Schober1, Stephan A Loer, Lothar A Schwarte
1Department of Anesthesiology, VU University Medical Center, Amsterdam, The Netherlands. P.Schober@vumc.nl
Abstract:
Monitoring of aortic blood flow, conducting large portions of the cardiac output (CO), allows conclusions on the global hemodynamic status of patients. For this purpose, transesophageal Doppler (TED) devices have been developed, which interrogate the descending aorta and calculate aortic blood flow velocity using the Doppler principle. The recorded velocity-time curve can be used to estimate CO as well other advanced hemodynamic parameters such as preload, afterload and myocardial contractility. Clinical studies in perioperative patients have demonstrated a reduced postoperative morbidity and shorter length of hospital stay when TED is used to guide fluid management. However, several assumptions are needed to translate the measured Doppler frequency shift to hemo- dynamic variables and discrepancies between the assumed and the actual condition may introduce a considerable risk for erroneous calculations. A correct interpretation of the displayed parameters requires profound knowledge on the technical basis of this method as well as its technical limitations. Our review focuses on these technical aspects which the clinician should be familiar with to allow proper use of TED monitoring devices.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Doppler Effect - II
Ultrasonography
During an ultrasonography procedure, a handheld device called a...