Separation of Uranium and Thorium for 230Th-U Dating of Submarine Hydrothermal Sulfides
Published on: May 20, 2019
Methods for spectral interference corrections for direct measurements of 234U and 230Th in materials by gamma-ray
1Turkish Atomic Energy Authority (TAEA), Besevler Yerleskesi, Tandogan, TR-06100, Ankara, Turkey. alfa.haluky@gmail.com
Abstract:
When the high-resolution gamma-ray spectrometry was used in the analysis of (234)U and (230)Th in samples, there is a much more need to correct for the measured activity results of (234)U and (230)Th mainly due to self-absorption effects and the interfering lines from (226)Ra, (235)U, (238)U and their decay products that often might be present in the samples. Therefore, in the present study, the methods for the spectral interference corrections for the analytical peaks of (234)U and (230)Th are suggested to take into account the contributions of the overlapping gamma rays to these peaks. For the method validation, direct gamma-ray spectrometric measurements were carried out using certified reference materials (CRM) by use of a 76.5 % n-type Ge detector. The activities measured for the CRM samples were corrected for spectral interferences, self-absorption and true coincidence-summing (TCS) effects. The obtained results indicate that ignoring of the contribution of the interference gamma rays to the main analytical peak at 53.2 keV of (234)U leads to a lager systematic error of 87.3-90.4 % for the measured activities of (234)U, and similarly if one ignores the contributions of the interference gamma rays to the main analytical peak at 67.7 keV of (230)Th, this leads to a much smaller systematic error of 2.1-2.7 % for the activities of (230)Th. Therefore, the required correction factors for spectral interferences to the analytical peaks of (234)U and (230)Th are not negligible and thus they should also be considered besides necessary self-absorption factors to determine more accurate activities in the samples. On the other hand, it is estimated that although the TCS effects on the main analytical peaks of both (234)U and (230)Th are negligibly small, those TCS correction factors for their interference gamma rays to these peaks should be taken into account when direct measurements are performed in a close-counting geometry condition. Otherwise, the resulted activities can have serious erroneous results for both (234)U and (230)Th while using gamma-ray spectrometry, thereby leading to inaccuracies in their derived quantities, for instance, the corresponding age determinations of the samples.
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference
UV–Vis Spectrometers
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Interaction of EM Radiation with Matter: Spectroscopy