Related Experiment Video
Updated: Jun 19, 2026

08:39
Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
Published on: January 28, 2019
Nonlinear phase change in type II second-harmonic generation under exact phase-matched conditions
Optics Letters
|October 22, 2009
Abstract:
The process of type II second-harmonic generation has been investigated theoretically. It is found that, unlike in the process of type I second-harmonic generation, phase matching is not necessary for a significant shift of the pump wave phase to be produced. The simple inequality of the intensities of interacting waves suffices for this effect to occur.
Related Concept Videos
Modes of Standing Waves - I
A close look at earthquakes provides evidence for the conditions appropriate for resonance, standing waves, and constructive and destructive interference. A building may vibrate for several seconds with a driving frequency matching the building's natural frequency of vibration; this produces a resonance that results in one building collapsing while the neighboring buildings do not. Often, buildings of a certain height are devastated, while other taller buildings remain intact. This phenomenon...
¹H NMR: Interpreting Distorted and Overlapping Signals
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Characteristics of Simple Harmonic Motion
The key characteristic of the simple harmonic motion is that the acceleration of the system and, therefore, the net force are proportional to the displacement and act in the opposite direction to the displacement. Additionally, the period and frequency of a simple harmonic oscillator are independent of its amplitude. For example, diving boards move faster or slower based on their thickness. A stiff, thick diving board has a large force constant, which causes it to have a smaller period, while a...
Phase Contrast and Differential Interference Contrast Microscopy
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Double Resonance Techniques: Overview
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...

