Optimal gradient operation in comprehensive liquid chromatography x liquid chromatography systems with limited
Filippo Bedani1, Wim Th Kok, Hans-Gerd Janssen
1Polymer-Analysis Group, Van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Nieuwe Achtergracht 166, 1018 WV Amsterdam, The Netherlands. F.Bedani@uva.nl
Abstract:
A novel strategy is described for designing optimal second dimension (2D) gradient conditions for a comprehensive two-dimensional liquid chromatography system where the two dimensions are not fully orthogonal. Using the approach developed here, the initial and final organic modifier content values resulting in the highest coverage of separation space can be derived for each 2D gradient run. Theory indicates that these values can be determined by adapting 2D gradient operation to the degree of orthogonality. The new method is tested on a comprehensive two-dimensional liquid chromatography system that uses reversed phase (RP) columns showing different selectivities in the two dimensions. A comparison between analyses carried out using normal and optimized 2D gradients showed that the latter allow a more efficient use of analysis time. This can result either in an improved peak capacity or in decreasing total analysis time, depending on the final goal of the experiment. In the latter scenario, the number of separated peaks is comparable to that obtained using gradients spanning a wide range of organic modifier but, now, in half the time. As test samples complex mixtures of peptides were analyzed.
More Related Videos
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Principles Of Column Chromatography
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...