Absolute Quantum Yield Measurement of Powder Samples
Published on: May 12, 2012
Reevaluation of absolute luminescence quantum yields of standard solutions using a spectrometer with an integrating
Kengo Suzuki1, Atsushi Kobayashi, Shigeo Kaneko
1Hamamatsu Photonics K. K., Joko-cho, Hamamatsu 431-3196, Japan.
Abstract:
We reevaluate the absolute fluorescence and phosphorescence quantum yields of standard solutions by using a novel instrument developed for measuring the absolute emission quantum yields of solutions. The instrument consists of an integrating sphere equipped with a monochromatized Xe arc lamp as the light source and a multichannel spectrometer. By using a back-thinned CCD (BT-CCD) as the detector, the sensitivity for spectral detection in both the short and long wavelength regions is greatly improved compared with that of an optical detection system that uses a conventional photodetector. Using this instrument, we reevaluate the absolute fluorescence quantum yields (Phi(f)) of some commonly used fluorescence standard solutions by taking into account the effect of reabsorption/reemission. The value of Phi(f) for 5 x 10(-3) M quinine bisulfate in 1 N H(2)SO(4) is measured to be 0.52, which is in good agreement with the value (0.508) obtained by Melhuish by using a modified Vavilov method. In contrast, the value of Phi(f) for 1.0 x 10(-5) M quinine bisulfate in 1 N H(2)SO(4), which is one of the most commonly used standards in quantum yield measurements based on the relative method, is measured to be 0.60. This value is significantly larger than Melhuish's value (0.546), which was estimated by extrapolating the value of Phi(f) for 5 x 10(-3) M quinine bisulfate solution to infinite dilution using the self-quenching constant. The fluorescence quantum yield of 9,10-diphenylanthracene in cyclohexane is measured to be 0.97. This system can also be used to determine the phosphorescence quantum yields (Phi(p)) of metal complexes that emit phosphorescence in the near-infrared region: the values of Phi(p) for [Ru(bpy)(3)](2+) (bpy = 2,2'-bipyridine) are estimated to be 0.063 in water and 0.095 in acetonitrile under deaerated conditions at 298 K, while that in aerated water, which is frequently used as a luminescent reference in biological studies, is reevaluated to be 0.040.
More Related Videos
06:08Time-resolved Photophysical Characterization of Triplet-harvesting Organic Compounds at an Oxygen-free Environment Using an iCCD Camera
Published on: December 27, 2018
06:06A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements
Published on: July 19, 2016
Related Concept Videos
Photoluminescence: Applications
UV–Vis Spectrometers