Published on: April 17, 2012
Less-restrictive, patient-specific radiation safety precautions can be safely prescribed after permanent seed
Lawrence T Dauer1, Marisa A Kollmeier, Matthew J Williamson
1Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY 10065, USA. dauerl@mskcc.org
Purpose:
To use radiation exposure rate measurements to determine patient-specific radiation safety instructions with the aim of reducing unnecessary precaution times and to evaluate potential doses to members of the public.
Methods And Materials:
Radiation exposure rate measurements were obtained from 1279 patients with Stage T1-2 prostate cancer who underwent transperineal (125)I or (103)Pd seed implantation from January 1995 through July 2008. An algorithm was developed from these measurements to determine the required precaution times to maintain public effective doses below 50% of the limits for specific exposure situations.
Results:
The median air kerma rates at 30 cm from the anterior skin surface were 4.9 microGy/h (range: 0.1-31.5) for (125)I and 1.5 microGy/h (range: 0.02-14.9) for (103)Pd. The derived algorithms depended primarily on the half-life T(p), the measured exposure rate at 30 cm, and specific exposure situation factors. For the typical (103)Pd patient, no radiation safety precautions are required. For the typical (125)I patient, no precautions are required for coworkers, nonpregnant adults who do not sleep with the patient, or nonpregnant adults who sleep with the patient. Typical (125)I patients should only avoid sleeping in the "spoon" position (i.e., in contact) with pregnant adults and avoid holding a child for long periods of time in the lap for about 2 months.
Conclusions:
The large number of cases available for this study permitted the development of an algorithm to simply determine patient-specific radiation safety instructions. The resulting precaution times are significantly less restrictive than those generally prescribed currently.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...