Related Experiment Video
Updated: Jun 19, 2026

HPLC Coupled with Chemical Fingerprinting for Multi-Pattern Recognition for Identifying the Authenticity of Clematidis Armandii Caulis
Published on: November 11, 2022
Development and validation of an HPLC method for the determination of process-related impurities in pridinol
Romina M Bianchini1, Patricia M Castellano, Teodoro S Kaufman
1Pharmaceutical Analysis, Department of Organic Chemistry, School of Pharmaceutical and Biochemical Sciences, National University of Rosario and Institute of Chemistry of Rosario (IQUIR, CONICET-UNR), Suipacha 531, Rosario (S2002LRK), Argentina.
Abstract:
A simple high performance liquid chromatographic method for the determination of process-related impurities in bulk drug of the central anticholinergic compound pridinol mesylate, has been developed and validated. Spectroscopically characterized synthetic impurities were used as standards. The chromatographic separation was optimized employing an experimental design strategy, and was achieved on a C(18) column with a mobile phase containing 50mM potassium phosphate buffer (pH 6.4), MeOH and 2-propanol (20:69:11, v/v/v), delivered at a flow rate of 1.0mLmin(-1). UV detection was performed at 245nm. The optimized method was thoroughly validated, demonstrating to be selective, when the chromatogram was recorded with a diode-array detector and peak purities were evaluated (>0.9995). The method is robust and linear (r(2)>0.99) over the range 0.05-2.5% (5-250% with regards to the 1% specification limit for both process-related impurities); it is also precise, regarding repeatability (RSD=1.5% for all of the analytes) and intermediate precision aspects and LOQ values for the impurities are below 0.01%. Method accuracy, evidenced by low bias of the results and analyte recoveries in the range of 99.1-102.7%, was assessed at five analyte concentration levels. The usefulness of the determination was also demonstrated through the analysis of different lots of pridinol mesylate bulk substance. The results indicate that the method is suitable for the quality control of the bulk manufacturing of pridinol mesylate drug substance.
More Related Videos
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Data Validation
Key parameters for method validation include:
High-Performance Liquid Chromatography: Instrumentation