The effect of oblique electron beams to the surface dose under the bolus
Bayram Demir1, Murat Okutan, Aydin Cakir
1Istanbul University, Science Faculty, Department of Physics, Istanbul, Turkey. bayramdemir69@yahoo.com
Abstract:
The aim of this study is to determine the effect of bolus to the surface dose in oblique electron incidences. Irradiations with 4.5, 6, 7.5, 9, and 12-MeV electron beams were made for the incidence angles of 0 degrees, 15 degrees, 30 degrees, 45 degrees, 60 degrees, 75 degrees and using 3 different bolus setups: (1) unbolused (no bolus), (2) 5-mm bolus, and (3) 10-mm bolus. A set of EBT gafchromic film pieces placed on the phantom surface was irradiated with a 400-cGy dose at D(max) for each setup. Whereas surface dose increased with increasing incidence degrees in the absence of a bolus, it was seen that there was a large surface dose decreasing in the presence of a bolus with increasing incidence angles. For 60 degrees incidence angle, the relative surface doses with unbolused setup were: 88.10%, 90.06%, 89.35%, 90.25%, and 97.10%; with 5-mm bolus: 66.45%, 81.20%, 99.78%, 124.43%, and 116.07%; and with 10-mm bolus: 22.65%, 45.20%, 55.20%, 65.82%, and 90.27% for 4.5, 6, 7.5, 9, and 12 MeV, respectively. The use of bolus in the treatment of highly oblique surfaces with low-energy electron beams significantly decreases the surface dose.
More Related Videos
Related Concept Videos
Scanning Electron Microscopy
Fundamental Principles
Accelerated...
Nuclear Overhauser Enhancement (NOE)
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Nonlinear Pharmacokinetics: Drug Elimination for IV Bolus Injection
Following the administration of a single intravenous (IV) bolus injection, we can determine the concentration of the drug in the plasma at any given time. This calculation is achieved using a specific equation that integrates the values of Vmax and KM.
We can also...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
Biological Effects of Radiation