Related Experiment Video
Updated: Jun 19, 2026

An Intestine/Liver Microphysiological System for Drug Pharmacokinetic and Toxicological Assessment
Published on: December 3, 2020
The performance of compartmental and physiologically based recirculatory pharmacokinetic models for propofol: a
Kenichi Masui1, Richard N Upton, Anthony G Doufas
1Department of Anesthesiology, National Defense Medical College, Tokorozawa, Japan.
Background:
With the growing use of pharmacokinetic (PK)-driven drug delivery and/or drug advisory displays, identifying the PK model that best characterizes propofol plasma concentration (Cp) across a variety of dosing conditions would be useful. We tested the accuracy of 3 compartmental models and 1 physiologically based recirculatory PK model for propofol to predict the time course of propofol Cp using concentration-time data originated from studies that used different infusion schemes.
Methods:
Three compartmental PK models for propofol, called the "Marsh," the "Schnider," and the "Schüttler" models, and 1 physiologically based recirculatory model called the "Upton" model, were used to simulate the time course of propofol Cp. To test the accuracy of the models, we used published measured plasma concentration data that originated from studies of manual (bolus and short infusion) and computer-controlled (target-controlled infusion [TCI] and long infusion) propofol dosing schemes. Measured/predicted (M/P) propofol Cp plots were constructed for each dataset. Bias and inaccuracy of each model were assessed by median prediction error (MDPE) and median absolute prediction error (MDAPE), respectively.
Results:
The M/P propofol Cp in the 4 PK models revealed bias in all 3 compartmental models during the bolus and short infusion regimens. In the long infusion, a worse M/P propofol Cp at higher concentration was seen for the Marsh and the Schüttler models than for the 2 other models. Less biased M/P propofol Cp was found for all models during TCI. In the bolus group, after 1 min, a clear overprediction was seen for all 3 compartmental models for the entire 5 min; however, this initial error resolved after 4 min in the Schnider model. The Upton model did not predict propofol Cp accurately (major overprediction) during the first minute. During the bolus and short infusion, the Marsh model demonstrated worse MDPE and MDAPE compared with the 3 other models. During short infusion, MDAPE for the Schnider and Schüttler models was better than the Upton and the Marsh models. All models showed similar MDPE and MDAPE during TCI simulations. During long infusion, the Marsh and the Schüttler models underestimated the higher plasma concentrations.
Conclusion:
When combining the performance during various infusion regimens, it seems that the Schnider model, although still not perfect, is the recommended model to be used for TCI and advisory displays.
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
Compartment Models: Two-Compartment Model
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Compartment Models: Single-Compartment Model
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
