Related Experiment Video
Updated: Jun 19, 2026

Highly Sensitive and Quantitative Detection of Proteins and Their Isoforms by Capillary Isoelectric Focusing Method
Published on: September 19, 2018
Postcolumn derivatization of proteins in capillary sieving electrophoresis/laser-induced fluorescence detection
Takashi Kaneta1, Daisuke Yamamoto, Totaro Imasaka
1Department of Applied Chemistry, Graduate School of Engineering, Kyushu University, Fukuoka, Japan. kaneta@cstf.kyushu-u.ac.jp
Abstract:
The separation methods for proteins with high resolution and sensitivity are absolutely important in the field of biological sciences. Capillary sieving electrophoresis (CSE) is an excellent separation technique for DNA and proteins with high resolution, while LIF permits the most sensitive detection in CSE. Therefore, proteins have to be labeled with fluorescent or fluorogenic reagent to produce fluorescent derivatives. Both precolumn and oncolumn derivatization have been employed for the labeling of proteins in CSE. However, there is no report on the postcolumn derivatization due to the limitation in the use of a standard migration buffer, despite it being a promising method for sensitive detection of proteins. Here, we show a novel postcolumn derivatization method for protein separation by CSE, using a tertiary amine as a buffer component in the running buffer. Tris, which is commonly used as a base in CSE separation buffers, was substituted by tertiary amines, 2-(diethylamino)ethanol and triethanolamine. A buffer solution containing 2-(diethylamino)ethanol or triethanolamine can be used for the CSE separation followed by the postcolumn derivatization of proteins, since both reagents are unreactive toward a fluorogenic labeling reagent, naphthalene-2,3-dicarbaldehyde. Thus, LIF detection using the postcolumn derivatization permits significant reduction in the LOD (by a factor of 2.4-28) of proteins, compared with conventional absorbance detection.
Related Concept Videos
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Capillary Electrophoresis: Instrumentation
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
