A TEST FOR DIFFUSIBLE IONS : II. THE IONIC NATURE OF PEPSIN

J H Northrop1

  • 1Laboratories of The Rockefeller Institute for Medical Research.

Related Concept Videos

Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
SDS-PAGE01:27

SDS-PAGE

Gel electrophoresis is a method that separates biological macromolecules like nucleic acids or proteins by forcing them to pass through a gel matrix under an electric field.
A variation of gel electrophoresis, termed  polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Titration of a Polyprotic Acid02:08

Titration of a Polyprotic Acid

A polyprotic acid contains more than one ionizable hydrogen and undergoes a stepwise ionization process. If the acid dissociation constants of the ionizable protons differ sufficiently from each other, then the titration curve for such polyprotic acid generates a distinct equivalence point for each of its ionizable hydrogens. Therefore, titration of a diprotic acid results in the formation of two equivalence points, whereas the titration of a triprotic acid results in the formation of three...
Qualitative Analysis03:46

Qualitative Analysis

For solutions containing mixtures of different cations, the identity of each cation can be determined by qualitative analysis. This technique involves a series of selective precipitations with different chemical reagents, each reaction producing a characteristic precipitate for a specific group of cations. Metal ions within a group are further separated by varying the pH, heating the mixture to redissolve a precipitate, or adding other reagents to form complex ions.
For instance, group IV...
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at the...
Ionic Strength: Overview01:12

Ionic Strength: Overview

The ionic strength of a solution is a quantitative way of expressing the total electrolyte concentration of a solution. This concept was first introduced in 1921 by two American physical chemists, Gilbert N. Lewis and Merle Randall, while describing the activity coefficient of strong electrolytes. During the calculation of ionic strength (I or μ), all the cations and anions are considered. However, the concentration (c) of an ion with a greater charge number (z) has a greater contribution to...