Related Experiment Video
Updated: Jun 19, 2026

Long-term Monitoring of Oxygen Consumption Rates in Highly Differentiated and Polarized Retinal Pigment Epithelial Cultures
Published on: August 16, 2024
THE RELATION BETWEEN FOVEAL VISUAL ACUITY AND ILLUMINATION UNDER REDUCED OXYGEN TENSION
1Fatigue Laboratory, Harvard University, Boston, Massachusetts, and the Department of Ophthalmology, Long Island College of Medicine, Brooklyn, New York.
Abstract:
1. The foveal visual acuity of eleven subjects was studied in relation to illumination under normal atmospheric conditions and at simulated altitudes of 10,000 feet (14.3 per cent O(2)) and 18,000 feet (10.3 per cent O(2)). A mask was used to administer the desired mixtures of oxygen and nitrogen. At the end of each experiment, measurements were made while inhaling 100 per cent oxygen from a cylinder. A red filter (No. 70 Wratten) was used so as to study only the behavior of the cones of the retina. 2. The logarithm of illumination was plotted horizontally (abscissa) and the logarithm of visual acuity vertically (ordinate). The reduced oxygen tensions resulted in a shift of the curve to the right, along the intensity axis, the extent of the change being 0.24 of a log unit at 14.3 per cent O(2) and 0.47 of a log unit at 10.3 per cent O(2). These effects were completely counteracted within a few minutes by inhaling oxygen. 3. As a consequence of the shape of the curve, such a shift to the right resulted in a relatively large decrease of visual acuity at low illuminations. At increasing light intensities anoxia produced less and less change, until at very high illuminations the decrease was negligible. Thus with 10.34 per cent O(2) the visual acuity at 0.144 photons decreased an average of 0.344 of a log unit, to 45 per cent of its normal value. At 1320 photons, however, it decreased only 0.026 of a log unit, to 94 per cent of its normal value for that intensity.
More Related Videos
Related Concept Videos
Photoreceptors and Visual Pathways
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Focusing of Light in the Eye
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...

