A system for recording high fidelity cough sound and airflow characteristics
W T Goldsmith1, A M Mahmoud, J S Reynolds
1National Institute for Occupational Safety and Health, Health Effects Laboratory Division, Pathology and Physiology Research Branch, 1095 Willowdale Road, Morgantown, WV 26505, USA. wbg4@cdc.gov
Abstract:
Cough is considered an early sign of many respiratory diseases. Recently, there has been increased interest in measuring, analyzing, and characterizing the acoustical properties of a cough. In most cases the main focus of those studies was to distinguish between involuntary coughs and ambient sounds over a specified time period. The objective of this study was to develop a system to measure high fidelity voluntary cough sounds to detect lung diseases. To further augment the analysis capability of the system, a non-invasive flow measurement was also incorporated into the design. One of the main design considerations was to increase the fidelity of the recorded sound characteristics by increasing the signal to noise ratio of cough sounds and to minimize acoustical reflections from the environment. To accomplish this goal, a system was designed with a mouthpiece connected to a cylindrical tube. A microphone was attached near the mouthpiece so that its diaphragm was tangent to the inner surface of the cylinder. A pneumotach at the end of the tube measured the airflow generated by the cough. The system was terminated with an exponential horn to minimize sound reflections. Custom software was developed to read, process, display, record, and analyze cough sound and airflow characteristics. The system was optimized by comparing acoustical reflections and total signal to background noise ratios across different designs. Cough measurements were also collected from volunteer subjects to assess the viability of the system. Results indicate that analysis of cough characteristics has the potential to detect lung disease.
Related Concept Videos
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Suctioning the Nasopharyngeal Airway
Equipment Required
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...