Related Experiment Video
Updated: Jun 19, 2026

Intracameral Injection in Rats with Low Risk of Adverse Effects
Published on: May 31, 2024
Inadvertent use of water-based ink instead of trypan blue in cataract surgery
Suleyman Kugu1, Gurkan Erdogan, Baran Kandemir
1Dr. Lutfi Kardar Kartal Training and Research Hospital, 1st Eye Clinic, Istanbul, Turkey.
Abstract:
We report a case of iris atrophy and corneal endothelial decompensation following the inadvertent use of water-based ink for capsular staining during cataract surgery. The anterior chamber was thoroughly irrigated with balanced salt solution after the identification of the wrong dye. Phacoemulsification with minimal ultrasound energy and intraocular lens implantation were performed without complications, and the operation was completed. The patient finally developed bullous keratopathy and underwent penetrating keratoplasty 4 months later.