CPOL: complex phase order likelihood as a similarity measure for MR-CT registration
Alexander Wong1, David A Clausi, Paul Fieguth
1Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, Canada N2L 3G1. a28wong@engmail.uwaterloo.ca
Abstract:
A novel similarity measure for registering magnetic resonance (MR) and computed tomography (CT) images has been designed and built. MR-CT registration methods often rely on the statistical intensity relationship between the images. The proposed similarity measure instead depends on the statistical relationship between the complex phase order between the images. By utilizing the complex phase order likelihood (CPOL) as a similarity measure, structural relationships instead of intensity relationships are explicitly used. This approach can be advantageous for MR-CT registration, where the intensities of the CT imagery have highly complex and nonlinear relationships with the intensities of corresponding MR imagery but simpler linear structural relationships. This new similarity measure has been tested on real MR-CT 3D volumes and has been evaluated based on fiducial registration error to determine alignment accuracy. Quantitative results show that CPOL is capable of achieving comparable alignment accuracy when compared to normalized mutual information, while being more robust to imaging artifacts such as noise.
More Related Videos
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...