Single photon emission computed tomography (SPECT) should be routinely performed for the detection of parathyroid
Damita L Thomas1, Twyla Bartel, Yusuf Menda
1Division of Nuclear Medicine, Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City, IA 52246, USA.
Rationale:
The current procedure guideline for performing dual-phase (DP) parathyroid scintigraphy, using technetium-99m sestamibi (Tc-99m MIBI) does not mandate the use of single photon emission computed tomography (SPECT) imaging for the detection of parathyroid adenoma (PA) or hyperplasia (PH). The aim of our study was to determine whether DP SPECT (DPS) is significantly superior to DP planar (DPP) imaging in the detection of these abnormalities, justifying its routine use with Tc-99m MIBI parathyroid scintigraphy.
Methods:
Thirty-six consecutive patients with biochemically-proven hyperparathyroidism who subsequently underwent surgical evaluation were studied. All patients underwent early and delayed planar and SPECT imaging at 15 and 90 minutes postinjection of 1.11 GBq (30 mCi) of Tc-99m MIBI. The sensitivity and false-positive rate of DPP and DPS Tc-99m MIBI scintigraphy were compared by retrospectively and blindly interpreting the images and comparing the results with surgical findings.
Results:
All 36 patients were shown to have either 1 PA (n=27), 2 PAs (n=1), or PH (n=8). Overall, 29 adenomas and 24 hyperplastic glands were found at surgery. On a per patient basis, the sensitivity for the detection of PA or PH for DPP was 42% (15/36) compared with 67% (24/36) for DPS (P = 0.03). For the detection of PAs, the sensitivity of DPP was 54% (15/28) versus 79% (22/28) for DPS (P = 0.05), whereas for the detection of PH, the sensitivities were 0% (0/8) for DPP versus 25% (2/8) for DPS (P = 0.13). There were 2 false-positive scans using DPP versus only 1 false-positive scan with DPS, resulting in false-positive rates of 7% and 4%, respectively. The combination of DPP and DPS did not add any advantage in detecting either PA or PH compared with DPS alone.
Conclusions:
DPS is significantly more sensitive, and at least as specific, compared with DPP in detecting parathyroid abnormalities in patients with primary hyperparathyroidism and should, therefore, be routinely used when DP Tc-99m MIBI is used in this setting. An algorithm for best utilization of this technique to determine the appropriate surgical approach in patients with primary hyperparathyroidism is presented.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT