Related Experiment Video
Updated: Jun 18, 2026

Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
New method of estimating wavelength-dependent optical path length ratios for oxy- and deoxyhemoglobin measurement
1Neuroscience Research Institute, National Institute of Advanced Industrial Science and Technology, Center 2, Umezono 1-1-1, Tsukuba, Ibaraki 305-8568, Japan. s.umeyama@aist.go.jp
Abstract:
In near-infrared spectroscopy (NIRS), concentration changes in oxy- and deoxyhemoglobin are calculated using an attenuation change of the measurement light and by solving a linear equation based on the modified Lambert-Beer law. While solving this equation, we need to know the wavelength-dependent mean optical path lengths of the measurement lights. However, it is very difficult to know these values by a continuous-wave-type (CW-type) system. We propose a new method of estimating wavelength-dependent optical path length ratios of the measurement lights based on the data obtained by a triple wavelength CW-type NIRS instrument. The proposed method does not give a path length itself, but it gives a path length ratio. Thus, it is possible to obtain the accurate hemoglobin concentration changes without cross talk, although the method cannot contribute to the quantification of the absolute magnitude of hemoglobin changes. The method is based on the principle that two possible estimations of hemoglobin concentration changes calculated using a triple-wavelength measurement system should be identical. The method was applied to the experimental data of human subjects' foreheads. The estimated path length ratios were very similar to literature values obtained by using picosecond laser pulses and a streak camera detector [M. Essenpreis et al., Appl. Opt. 32(4), 418-425 (1993)].
Related Concept Videos
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
IR and UV–Vis Spectroscopy of Aldehydes and Ketones
UV–Vis Spectroscopy: Beer–Lambert Law
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
UV–Vis Spectroscopy: Woodward–Fieser Rules

