Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
Interobserver variability in the assessment of CT imaging features of traumatic brain injury
Kimberly A Chun1, Geoffrey T Manley, Shirley I Stiver
1Department of Radiology, Neuroradiology Section, University of California-San Francisco , San Francisco, California 94143-0628, USA.
Abstract:
The goal of our study was to determine the interobserver variability between observers with different backgrounds and experience when interpreting computed tomography (CT) imaging features of traumatic brain injury (TBI). We retrospectively identified a consecutive series of 50 adult patients admitted at our institution with a suspicion of TBI, and displaying a Glasgow Coma Scale score < or =12. Noncontrast CT (NCT) studies were anonymized and sent to five reviewers with different backgrounds and levels of experience, who independently reviewed each NCT scan. Each reviewer assessed multiple CT imaging features of TBI and assigned every NCT scan a Marshall and a Rotterdam grading score. The interobserver agreement and coefficient of variation were calculated for individual CT imaging features of TBI as well as for the two scores. Our results indicated that the imaging review by both neuroradiologists and neurosurgeons were consistent with each other. The kappa coefficient of agreement for all CT characteristics showed no significant difference in interpretation between the neurosurgeons and neuroradiologists. The average Bland and Altman coefficients of variation for the Marshall and Rotterdam classification systems were 12.7% and 21.9%, respectively, which indicates acceptable agreement among all five reviewers. In conclusion, there is good interobserver reproducibility between neuroradiologists and neurosurgeons in the interpretation of CT imaging features of TBI and calculation of Marshall and Rotterdam scores.
More Related Videos
Related Concept Videos
Traumatic Brain Injury l: Introduction
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic Stimulation (TMS).