Noninvasive assessment of central and peripheral arterial pressure (waveforms): implications of calibration methods
Dries Mahieu1, Jan Kips, Ernst R Rietzschel
1Department of Pharmacology, Belgium. dries.mahieu@ugent.be
Objectives:
Noninvasive estimation of central blood pressure (BP) from radial artery pressure waveforms is increasingly applied. We investigated the impact of radial artery waveform calibration on central BP assessment and calculated pressure amplification, with focus on the one-third rule used to estimate mean arterial BP (MAP).
Methods:
Pressure waveforms were noninvasively measured at the radial and carotid arteries in 1873 individuals (age 45.8+/-6.1 years). Radial and carotid artery waveforms were calibrated using brachial artery DBP and SBP, MAP estimated with the one-third rule and MAP estimated as brachial DBP along with 40% of brachial artery pulse pressure.
Results:
Central SBP obtained via a transfer function was 123.5 +/- 15.7, 117.8 +/- 14.2 and 126.0 +/- 15.4 mmHg (mean +/- SD) following above-mentioned three calibration schemes, respectively. Using the same calibration schemes, carotid artery SBP was 131.4 +/- 15.2, 118.4 +/- 14.4 and 126.8 +/- 15.7 mmHg, respectively. Central-to-brachial amplification was 13.0 +/- 3.6 mmHg using second method as compared with 4.6 +/- 3.8 mmHg with third method. Brachial-to-radial amplification was actually negative (-6.3 +/- 4.5 mmHg) using second method, whereas 3.4 +/- 5.5 mmHg was found with third method.
Conclusion:
Both carotid artery SBP and central SBP obtained via a transfer function are highly sensitive to the calibration of the respective carotid artery and radial artery pressure waveforms. Our data suggest that the one-third rule to calculate MAP from brachial cuff BP should be avoided, especially when used to calibrate radial artery pressure waveforms for subsequent application of a pressure transfer function. Until more precise estimation methods become available, it is advisable to use 40% of brachial pulse pressure instead of 33% to assess MAP.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: