Related Experiment Video
Updated: Jun 18, 2026

Echocardiographic Assessment of Cardiac Anatomy and Function in Adult Rats
Published on: December 13, 2019
Pulse wave analysis of the aortic pressure waveform in severe left ventricular systolic dysfunction
Scott J Denardo1, Ramavathi Nandyala, Gregory L Freeman
1Division of Cardiovascular Medicine, University of Florida College of Medicine, Gainesville, FL 32610, USA. scott.denardo@medicine.ufl.edu
Background:
The effect of moderate left ventricular systolic dysfunction (LVSD) on ventricular/vascular coupling and the aortic pressure waveform (AoPW) has been well described, but the effect of severe LVSD has not.
Methods And Results:
We used noninvasive, high-fidelity tonometry of the radial artery and a mathematical transfer function to generate the AoPW in 25 treated patients with LVSD (mean LV ejection fraction, 24+/-8.8%; range, 11% to 40%; 21 patients <30%). Pulse wave analysis of the AoPW was used to characterize ventricular/vascular coupling and compared with pulse wave analysis performed in 25 normal subjects matched for age, gender, height, body mass index, and heart rate. Measurements obtained using pulse wave analysis in LVSD patients indicated features of poor LV stroke performance and also reduced indices of arterial stiffness: increased travel time of the pressure wave (147+/-10 ms versus 132+/-21 ms; P<0.001); decreased systolic duration of reflected wave (134+/-24 ms versus 167+/-26 ms; P<0.001); ejection duration (277+/-22 ms versus 299+/-25 ms; P<0.008); percent systolic duration (32+/-5.3% versus 35+/-4.0%; P<0.02); aortic systolic pressure (100+/-16 mm Hg versus 121+/-16 mm Hg; P<0.001); unaugmented pressure (24+/-6.3 mm Hg versus 32+/-6.4 mm Hg; P<0.001); augmented pressure (4.8+/-3.1 mm Hg versus 9.6+/-4.5 mm Hg; P<0.001); pulse pressure (28+/-7.4 mm Hg versus 42+/-9.5 mm Hg; P<0.001); augmentation index (12+/-6.6% versus 23+/-7.6%; P<0.006); wasted LV effort (5.3+/-2.8x10(2) dyne sec/cm(2) versus 17+/-10x10(2) dyne sec/cm(2); P<0.001); systolic pressure time index (17+/-4.1x10(2) mm Hg-sec/min versus 23+/-4.2x10(2) mm Hg sec/min; P<0.001); and pressure systolic area (383+/-121 mm Hg sec/min versus 666+/-150 mm Hg sec/min; P<0.001).
Conclusions:
Severe LVSD causes measurable changes in the AoPW. Standardization of AoPW findings in LVSD patients may allow for the clinical use of radial artery pulse wave analysis to noninvasively determine the severity of dysfunction and aid in logical therapy.
Related Concept Videos
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Aortic Regurgitation I: Introduction
Pulse
The pulse serves as a clinical indicator...
Measurement of Blood Pressure
