Related Experiment Video
Updated: Jun 18, 2026

Subject-specific Musculoskeletal Model for Studying Bone Strain During Dynamic Motion
Published on: April 11, 2018
A three-dimensional finite element model of maximal grip loading in the human wrist
M K Gislason1, D H Nash, A Nicol
1Bioengineering Unit, University of Strathclyde, Glasgow, UK. magnus.gislason@strath.ac.uk
Abstract:
The aim of this work was to create an anatomically accurate three-dimensional finite element model of the wrist, applying subject-specific loading and quantifying the internal load transfer through the joint during maximal grip. For three subjects, representing the anatomical variation at the wrist, loading on each digit was measured during a maximal grip strength test with simultaneous motion capture. The internal metacarpophalangeal joint load was calculated using a biomechanical model. High-resolution magnetic resonance scans were acquired to quantify bone geometry. Finite element analysis was performed, with ligaments and tendons added, to calculate the internal load distribution. It was found that for the maximal grip the thumb carried the highest load, an average of 72.2 +/- 20.1 N in the neutral position. Results from the finite element model suggested that the highest regions of stress were located at the radial aspect of the carpus. Most of the load was transmitted through the radius, 87.5 per cent, as opposed to 12.5 per cent through the ulna with the wrist in a neutral position. A fully three-dimensional finite element analysis of the wrist using subject-specific anatomy and loading conditions was performed. The study emphasizes the importance of modelling a large ensemble of subjects in order to capture the spectrum of the load transfer through the wrist due to anatomical variation.
Related Concept Videos
Three-Dimensional Force System
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi radialis,...
Normal Strain under Axial Loading
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
