Fourier Domain Optical Coherence Tomography integrated into a slit lamp; a novel technique combining anterior and
M Stehouwer1, F D Verbraak, H de Vries
1Department of Ophthalmology, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands. m.stehouwer@amc.uva.nl
Purpose:
Fourier Domain Optical Coherence Tomography (FD-OCT) provides high resolution cross-sectional images of the retina and the anterior segment. It has become an important tool in ophthalmology in the examination, diagnosis, and treatment of important and common diseases. Present OCT imaging systems are stand-alone devices. The aim of this paper is to show the quality of images made with a prototype of a Fourier Domain (FD-) OCT imaging system (SLSCAN-1) integrated into a slit lamp.
Methods:
Different representative pathologies of the posterior and anterior segment were observed with the slit lamp and simultaneously scanned with a prototype of the slit lamp-integrated FD-OCT system. The clinical interpretation of posterior segment images made with the prototype were compared to those obtained with a stand-alone FD-system (3D-OCT-1000 Mark II, Topcon).
Results:
Images made with the slit lamp-integrated FD-OCT were of sufficient quality to allow for a correct interpretation of the observed pathological conditions. Conclusions based on the images of the posterior segment of the prototype were identical to the conclusions based on the images of a stand-alone FD-system (3D-OCT-1000 Mark II, Topcon). In addition to the images of the posterior segment, images could be made of the anterior segment. The OCT system did not interfere with the normal functionality of the slit lamp.
Conclusion:
The slit lamp-integrated FD-OCT system provided high quality images of both the anterior and the posterior segment. Scans made with the slit lamp-integrated FD-OCT system could be of use in clinical practice.
More Related Videos
Related Concept Videos
Confocal Fluorescence Microscopy
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Total Internal Reflection Fluorescence Microscopy
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Super-resolution Fluorescence Microscopy