Related Experiment Video
Updated: Jun 18, 2026

A Standardized Method for Measurement of Elbow Kinesthesia
Published on: October 10, 2020
Elbow joint position sense after neuromuscular training with handheld vibration
Brady L Tripp1, Donald Faust, Patrick Jacobs
1Department of Applied Physiology & Kinesiology, College of Health and Human Performance, FLG 148, University of Florida, PO Box 118205, Gainesville, FL 32611-8205, USA. trippb@hhp.ufl.edu
Context:
Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited.
Objective:
To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity.
Design:
Crossover study.
Setting:
University athletic training research laboratory.
Patients Or Other Participants:
Thirty-one healthy, college-aged volunteers (16 men, 15 women, age = 23 + or - 3 years, height = 173 + or - 8 cm, mass = 76 + or - 14 kg).
Intervention(S):
We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90 degrees ) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds.
Main Outcome Measure(S):
We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles.
Results:
Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P < or = .005), whereas 5-Hz vibration did not affect accuracy (F(1,61) = 2.625, P = .100) but did decrease variability (F(1,61) = 7.250, P = .009). The control condition and 0-Hz training protocol had no effect on accuracy or variability (P > or = .200).
Conclusions:
Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury.
Related Concept Videos
Spinal Nerves: Plexus I
The Cervical Plexus
The cervical plexus, formed by the anterior rami of the first four...
Muscles that Move the Forearm
Forearm Flexors
The biceps brachii, brachialis, and brachioradialis are forearm flexors. The biceps brachii is made up of two heads. Its long head originates at the supraglenoid tubercle of the scapula, whereas that of the short head is...