Reliability of anal pressure measurements
1Gastroenterologisches Institut, Wiesbaden, Federal Republic of Germany.
Abstract:
This study investigates whether measurements of anal sphincter pressure and length are reproducible and whether visual analyses of manometric tracings are reliable. Manometric studies were performed on three different days in 10 male and 10 female healthy subjects with the use of a pneumohydraulic capillary perfusion system. There was complete agreement between both observers in the analysis of anal resting and squeeze pressure as well as sphincter length. The pressure profiles from different days correlated significantly (P less than 0.01) with each other regardless of whether the studies were performed in the prepared or unprepared bowel. However, anal sphincter length and the quality of the anorectal inhibitory reflex varied greatly on different days. Male and female subjects showed major differences in the capacity of the anal sphincter to contract voluntarily (P less than 0.01), but resting tone and sphincter length were comparable in the two groups. It is concluded that pressure determinations in the anal canal are reliable and reproducible, but that alterations in the quality of the anorectal reflex need to be confirmed by repeated measurements before pathology is diagnosed.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...