Sumito Narita1, Koji Miyamoto, Takeshi Tsuchiya
1EP Expert Doctors-Team Tsuchiya, Japan.
Background:
Atrial tachycardia (AT) is sometimes difficult to eliminate by radiofrequency ablation (RFA), but the EnSite array (EA) visualizes the beat-to-beat virtual activation of any tachycardia.
Methods And Results:
The 51 patients with 74 ATs (mean age 57+/-18 years, 28 males) undergoing EA-guided RFA were included; 14 patients had had previous open heart surgery and 5 had organic heart disease. RFA was performed at the AT focus for focal AT (n=48) with an endpoint of AT termination and subsequent non-inducibility. RFA was performed at a critical conducting pathway for reentrant AT (n=26) with creation of a block line in the critical reentry circuit. EA revealed that 57 ATs originated in the right atrium (77%) and 17 originated in the left atrium (23%); all but 1 were successfully eliminated. Fluoroscopic time was 19+/-11 min, the number of RFA applications was 8+/-7, and the radiofrequency energy was 10,711+/-12,655 J. No complications were noted. All but 2 patients were free of any symptoms during a follow-up of 16+/-9 months.
Conclusions:
EA-guided RFA is safe and effective for AT, irrespective of its mechanism, sustainability or origin, and regardless of underlying heart disease. (Circ J 2010; 74: 59 - 65).