Related Experiment Video
Updated: Jun 18, 2026

Determination of Continuity Index Values in Atrial Fibrillation Ablation with Proactive Esophageal Cooling
Published on: April 19, 2024
The thorough QT/QTc study 4 years after the implementation of the ICH E14 guidance
1Department of Clinical Science and Education, Section of Cardiology, Karolinska Institute, South Hospital, Stockholm, Sweden. borje.darpo@telia.com
Abstract:
The ICH E14 guidance on how to clinically assess a new drug's liability to prolong the QT interval was adopted in May 2005. A centre-piece of the guidance was the establishment of one single trial, the 'thorough QT/QTc study', intended to confidently identify drugs that may cause QT prolongation. Initially perceived as a great challenge, this study has rapidly become a standard component of all clinical development programs for new molecular entities. The study is normally conducted in healthy volunteers, includes both a positive and a negative (placebo) control and is stringently powered to exclude an effect on the QTc interval exceeding 10 ms. The E14 guidance was intentionally not very prescriptive and allowed sponsors and service providers to explore new methodologies. This has allowed for a rapid development of new methods during the first years after the guidance's implementation, such as computer-assisted algorithms for QT measurements. Regulators have worked in close collaboration with pharmaceutical industry to set standards for the design and conduct of the 'thorough QT/QTc study', which therefore has evolved as a key component of cardiac safety assessment of new drugs. This paper summarizes the requirements on the 'thorough QT/QTc study' with emphasis on the standard that has evolved based on interactions between regulators and sponsors and the experience from a large number of completed studies.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Clinical Trials: Overview
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...