Pulse pressure power spectrum predicts volume responsiveness in shock patients without sedation
Chih-Hsin Lee1, Jann-Yuan Wang, Yao-Kuang Wu
1Graduate Institute of Physiology, National Defense Medical Center, Taiwan and Medical Intensive Care Unit, Buddhist Tzu Chi General Hospital, Taipei Branch, Taipei, Taiwan.
Abstract:
The authors investigated whether the pulse pressure power spectrum (PPPS) could predict the effect of volume expansion (VE) in shock patients under mechanical ventilation without sedation. The PPPS within a frequency band of 0.15 to 0.75 Hz was developed with an animal model using nine domesticated piglets simulating acute hemorrhagic shock and then validated in 17 nonsedated mechanically ventilated shock patients. Hemodynamic parameters were recorded before and after VE. In the animal model under anesthesia and pressure-controlled ventilation, the absolute and proportional change of cardiac index after VE (DeltaCI and DeltaCI%) positively correlated with the square root of PPPS (SQRT-PPPS, r(2) = 0.34 and r(2) = 0.72, respectively). The correlations were weaker with PP variation averaged on 120-s sliding window (PPV120, r(2)= 0.27 and r(2)= 0.64, respectively) and PPV30 (r(2)= 0.28 and r(2)= 0.63, respectively) under pressure-controlled level 10 cmH(2)O. Defining the volume responder as DeltaCI% greater than or equal to 15%, the area under the receiver operating characteristic curve (AROC) were equivalent for SQRT-PPPS (0.91), PPV120 (0.86), and PPV30 (0.85). For the 17 patients who had spontaneous breathing movements under assisted pressure-controlled ventilation, the DeltaCI and DeltaCI% positively correlated with SQRT-PPPS (r(2) = 0.35 and r(2)= 0.73, respectively). The correlations were weaker with PPV120 (r(2)= 0.27 and r(2) = 0.42) and PPV30 (r(2) = 0.27 and r(2)= 0.40). The AROC were 0.78 for SQRT-PPPS (P = 0.047), 0.71 for PPV120 (P = 0.131), and 0.69 for PPV30 (P = 0.185). In mechanically ventilated shock patients, SQRT-PPPS predicts volume responsiveness without the need for sedation to prevent spontaneous breathing movements.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulse
The pulse serves as a clinical indicator...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...