Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Positron Emission Tomography01:29

Positron Emission Tomography

Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Dosimetric comparison of intensity modulated proton therapy and knowledge-based volumetric arc therapy for left-sided breast cancer.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2026
Same author

Development of a breathing lung phantom for proton CT imaging.

Physics in medicine and biology·2025
Same author

LET<sub>d</sub> Optimization Verification With an SOI Microdosimeter.

International journal of radiation oncology, biology, physics·2024
Same author

Microdosimetry of a 62-MeV clinical proton beam with five detectors.

Radiation protection dosimetry·2023
Same author

Ultrasound Localization of Nitinol Wire of Sub-Wavelength Dimension.

IEEE open journal of engineering in medicine and biology·2022
Same author

Evaluation of the impact of a scanner prototype on proton CT and helium CT image quality and dose efficiency with Monte Carlo simulation.

Physics in medicine and biology·2022

Related Experiment Video

Updated: Jun 18, 2026

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

A more accurate reconstruction system matrix for quantitative proton computed tomography.

S N Penfold1, A B Rosenfeld, R W Schulte

  • 1Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales 2522, Australia. snp75@uow.edu.au

Medical Physics
|November 26, 2009
PubMed
Summary

Accurate proton CT (pCT) imaging requires an improved system matrix. This study introduces an effective mean chord length, significantly reducing stopping power errors and enhancing computational efficiency for quantitative pCT reconstructions.

More Related Videos

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

Related Experiment Videos

Last Updated: Jun 18, 2026

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
10:24

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Published on: May 7, 2021

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
09:21

Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images

Published on: February 18, 2015

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
14:19

A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space

Published on: February 1, 2016

Area of Science:

  • Medical Imaging
  • Computational Physics
  • Radiological Sciences

Background:

  • Quantitative proton CT (pCT) image reconstruction relies on an accurate system matrix.
  • Previous methods using constant intersection chord lengths introduced systematic errors in proton stopping power calculations.
  • Improving the system matrix accuracy is crucial for reliable pCT data.

Purpose of the Study:

  • To develop a computationally efficient variable intersection chord length for enhanced system matrix accuracy in pCT.
  • To reduce systematic errors in reconstructed proton stopping powers.
  • To improve the overall accuracy and efficiency of quantitative pCT image reconstruction.

Main Methods:

  • Developed an analytical expression for an angle-dependent effective mean chord length function, accounting for the discrete nature of pCT most likely path (MLP) reconstruction.
  • Simulated a pCT dataset using GEANT4 with 200 MeV protons and a head phantom.
  • Reconstructed phantom stopping powers using algebraic reconstruction technique with constant, exact, and effective mean chord length approaches.

Main Results:

  • The effective mean chord length approach reduced mean reconstructed stopping power errors from approximately 10% to less than 0.5%.
  • Reconstructions using the effective mean chord length were approximately 20% faster than those using the exact chord length.
  • Both effective mean chord length and exact chord length methods significantly outperformed the constant chord length approach.

Conclusions:

  • The effective mean chord length method significantly improves the accuracy of the system matrix for quantitative pCT.
  • This approach offers a computationally efficient alternative to exact chord length calculations.
  • The effective mean chord length method enables more accurate and efficient quantitative pCT reconstructions.