Rapid and chemically selective nicotine quantification in smokeless tobacco products using GC-MS
Stephen B Stanfill1, Lily T Jia, David J Ashley
1U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Laboratory Sciences, Emergency Response and Air Toxicants Branch, Atlanta, Georgia 30341-3719, USA.
Abstract:
In recent years, there has been a rapid proliferation of smokeless products with a wide range of nicotine content and flavoring formulations that may appeal to new users and existing cigarette smokers. The CDC nicotine method, which employs gas chromatography-flame ionization detection (GC-FID), provides a robust means for measuring nicotine in smokeless tobacco. However, several compounds, identified in a few flavored smokeless products, interfere with nicotine quantification using GC-FID. In response, the standard nicotine method (26.7 min run time) was modified to use faster GC ramping (3.7 min run time) and detection with mass spectrometry (GC-MS) in selected ion-monitoring mode to reduce signal interferences that can bias nicotine values. Seven conventional smokeless samples (n = 12) and blank tobacco samples spiked at three nicotine concentration levels (n = 5) were analyzed using the GC-FID and GC-MS methods and found to be in excellent agreement. However, only the GC-MS method provided confirmation of chromatographic peak purity in certain highly flavored products. The GC-MS method is not intended to replace the GC-FID method but to provide a method versatile enough to analyze a wide range of nicotine values in domestic and international samples of varying complexity. Accurate nicotine quantification is important for determining total nicotine content in tobacco and in subsequent calculations of un-protonated nicotine content.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...