Related Experiment Video
Updated: Jun 18, 2026

Mechanical Ventilation Boot Camp Curriculum
Published on: March 12, 2018
[Clinical investigation on the compliance and the validity of ventilator bundle]
Hai-jing Song1, Jing-tao Liu, Su-qin Gao
1The Critical Care Medicine Department of the 309th Hospital of PLA, Beijing 100091, China.
Objective:
To investigate the compliance of ventilator bundle implementation and its preventive effect on ventilator associated pneumonia (VAP).
Methods:
A before and after design was used in this single center study. Patients aged from 18 to 80 years, with mechanical ventilation (MV) duration over 48 hours were recruited during 1 year before (control group) and 2 years after bundle implementation (intervention group). Measurements included the rate of successful ventilator bundle implementation in intervention group, incidence of VAP, duration of MV and mortality within 28 days in both groups.
Results:
A total number of 237 patients, including 71 patients in control arm and 166 patients in intervention arm, were recruited in this study. There was no statistical significance in ratio of sex, mean age, category of diseases or mean acute physiology and chronic health evaluation II (APACHE II) score between two groups (all P>0.05). Significant changes were not found in MV duration [(5.9+/-5.6) days vs. (5.2+/-6.1) days], incidence of VAP (21.1% vs. 20.5%) and mortality within 28 days (16.9% vs. 19.8%) between control and intervention group as well. In intervention group, 57 of 166 (34.3%) patients were successfully implemented all of four ventilator bundle items. The successful rate of ventilator bundle implementation were 62.5% (35/56), 22.1% (21/95) and 6.7% (1/15) in patients received MV duration < or =3 days, 4-7 days and >7 days respectively. Among the four items of the bundle, head of bed elevation > or =30 degree angle had the lowest successful rate [43.4% (72/166)]. But it was much better in the implementation of daily wake-up plus weaning, prevention of peptic ulcer and prevention of deep vein thrombosis formation [92.2% (153/166), 88.0% (146/166) and 83.1% (138/166) respectively].
Conclusion:
The poor compliance of ventilator bundle is an important factor in impacting the efficacy of ventilator bundle.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...