Drug impurity profiling: Method optimization on dissimilar chromatographic systems: Part I: pH optimization of the
M Dumarey1, R Sneyers, W Janssens
1Analytical Chemistry and Pharmaceutical Technology, Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, 1090 Brussels, Belgium.
Abstract:
The use of dissimilar chromatographic systems in drug impurity profiling can be very advantageous. Screening a new-drug impurity mixture on those systems not only enhances the chance that all impurities are revealed, but also allows choosing a suited system for further method development. In this paper several strategies were evaluated to predict the optimal pH (of the buffer used in the mobile phase) from the screening results. Four or five dissimilar stationary phases were screened at four pH values (between 2.5 and 9.4), in order to obtain maximal information about the composition of the sample and to select one column for the subsequent optimization. Different linear models (straight lines, 2nd and 3rd degree polynomials) based on these experiments were tested for their ability to predict the retention times (t(R)) of the impurities at intermediate pH values. The predicted t(R) values were then used to calculate minimal resolutions and eventually to select an optimal pH at which the highest minimal resolution is predicted. None of the applied models is accurate enough to predict correctly which peaks are worst separated at the indicated optimal pH. However, the best strategy (applying a second degree polynomial describing the t(R) measured at 3 consecutive screening pH values) did succeed in indicating an optimal pH at which a good separation of the impurities is obtained. Unfortunately, the resulting separation quality is not or only slightly better than the best separation obtained during screening. Therefore, it can be concluded that the most (time-) efficient approach to develop an impurity profile of a new drug is to screen it on four or five dissimilar columns at four different pH values and to retain the best screening conditions (without making predictions for intermediate conditions) for further optimization of the organic modifier composition of the mobile phase, and occasionally the temperature and the gradient. This is at least the case when the profiles have a complexity similar to those studied.
More Related Videos
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Principles Of Column Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...