Related Experiment Video
Updated: Jul 12, 2026

Biochemical Measurement of Neonatal Hypoxia
Published on: August 24, 2011
Analytical goals for determinations of theophylline concentration in serum
1Wadsworth Center for Laboratories and Research, New York State Department of Health, Albany 12201-0509.
Abstract:
Statistical principles for analytical goal-setting were applied to two medical applications of drug-monitoring data: (a) individualizing dosage requirements by reference to a population-based therapeutic range or to a patient-specific decision value determined by Bayesian decision analysis, and (b) prospective dosing by using pharmaco-kinetic principles. For application a, the analytical goal for total allowable analytical error (TE) was defined as the amount of error that does not decrease by more than 5% either the sensitivity (probability) for detecting dosage regimens that may require modification or the specificity for detecting appropriately dosed patients. The limiting factor in achievable sensitivity and specificity was the intra-individual variation of peak steady-state concentration (Css), with the TE determined to be a CV of 4%. For application b, error-propagation rules were applied to a proposed prospective dosing scheme (J Pharmacokinet Biopharm 1978;6:135-51). The TE was determined to depend on the rate of theophylline clearance. For clearance rates less than or equal to 0.6 mL/(kg.min), the TE (CV) must not exceed 3% if the predicted infusion rate is to produce, with 95% confidence, a concentration within the therapeutic range.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:38Simultaneous Quantification of Selected Kynurenines Analyzed by Liquid Chromatography-Mass Spectrometry in Medium Collected from Cancer Cell Cultures
Published on: May 9, 2020
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the lowest drug...
Drug Concentrations: Measurements
Plasma —...
Determination of Michaelis Constant and Maximum Elimination Rate
These parameters can be estimated by analyzing plasma concentration data post-drug administration. A notable example of this application is phenytoin, a drug with capacity-limited kinetics. It's recommended that phenytoin should be administered at two...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
IV Infusion to Oral Dosing: Conversion Methods
Therapeutic Drug Monitoring: Drug Analysis Methods