Related Experiment Video
Updated: Jun 18, 2026

Lesion Explorer: A Video-guided, Standardized Protocol for Accurate and Reliable MRI-derived Volumetrics in Alzheimer's Disease and Normal Elderly
Published on: April 14, 2014
The Microbleed Anatomical Rating Scale (MARS): reliability of a tool to map brain microbleeds
S M Gregoire1, U J Chaudhary, M M Brown
1Stroke Research Group, National Hospital for Neurology and Neurosurgery, Queen Square, London WC1N 3BG, UK.
Objective:
Brain microbleeds on gradient-recalled echo (GRE) T2*-weighted MRI may be a useful biomarker for bleeding-prone small vessel diseases, with potential relevance for diagnosis, prognosis (especially for antithrombotic-related bleeding risk), and understanding mechanisms of symptoms, including cognitive impairment. To address these questions, it is necessary to reliably measure their presence and distribution in the brain. We designed and systematically validated the Microbleed Anatomical Rating Scale (MARS). We measured intrarater and interrater agreement for presence, number, and anatomical distribution of microbleeds using MARS across different MRI sequences and levels of observer experience.
Methods:
We studied a population of 301 unselected consecutive patients admitted to our stroke unit using 2 GRE T2*-weighted MRI sequences (echo time [TE] 40 and 26 ms). Two independent raters with different MRI rating expertise identified, counted, and anatomically categorized microbleeds.
Results:
At TE = 40 ms, agreement for microbleed presence in any brain location was good to very good (intrarater kappa = 0.85 [95% confidence interval (CI) 0.77-0.93]; interrater kappa = 0.68 [95% CI 0.58-0.78]). Good to very good agreement was reached for the presence of microbleeds in each anatomical region and in individual cerebral lobes. Intrarater and interrater reliability for the number of microbleeds was excellent (intraclass correlation coefficient [ICC] = 0.98 [95% CI 0.97-0.99] and ICC = 0.93 [0.91-0.94]). Very good interrater reliability was obtained at TE = 26 ms (kappa = 0.87 [95% CI 0.61-1]) for definite microbleeds in any location.
Conclusion:
The Microbleed Anatomical Rating Scale has good intrarater and interrater reliability for the presence of definite microbleeds in all brain locations when applied to different MRI sequences and levels of observer experience.