Magnetic resonance-based deep brain stimulation technique: a series of 478 consecutive implanted electrodes with no perioperative intracerebral hemorrhage
Related Experiment Video
Updated: Jun 18, 2026

Deep Brain Stimulation with Simultaneous fMRI in Rodents
Published on: February 15, 2014
Igor Lima Maldonado1, Thomas Roujeau, Laura Cif
1Department of Neurosurgery, Research Unit on Movement Disorders, University Hospital of Montpellier, Montpellier, France.
Objective:
The aim of this study was to determine the safety of a deep brain stimulation technique consisting of a combination of routine general anesthesia, magnetic resonance imaging direct targeting, and a single penetration technique in a large population of patients undergoing operation for movement disorders.
Methods:
One hundred ninety-four patients treated with deep brain stimulation between 1996 and 2007 were assessed via a computerized database for intra- and perioperative events. Most patients were young; only 62 of them were older than 40 years (mean age, 31.1 years). General anesthesia was induced in all cases before placement of a magnetic resonance imaging-compatible stereotactic frame. Electrode implantation was done under radioscopic control via a rigid immobile cannula using a single cerebral perforation. No perioperative microelectrode recording or neurostimulation testing was used. Systematic postoperative magnetic resonance imaging was performed before frame removal.
Results:
A total of 478 electrodes were implanted in 220 procedures: 426 for dystonic-dyskinetic syndromes and 52 for Parkinson disease. The mean number of parenchymal penetrations per patient was 2.5 for the dystonic-dyskinetic syndrome group and 2.08 for the Parkinson disease group. Postimplantation magnetic resonance imaging detected no perioperative intraparenchymal hemorrhages.
Conclusion:
We consider that the risk of hemorrhagic complication is multifactorial but closely related to the chosen technique.