The validity of wireless iButtons and thermistors for human skin temperature measurement
A D Harper Smith1, D R Crabtree, J L J Bilzon
1Extremes Research Group, Bangor University, Bangor LL572PZ, UK.
Abstract:
Skin temperature is a fundamental variable in human thermo-physiology, and yet skin temperature measurement remains impractical in most free-living, exercise and clinical settings, using currently available hard-wired methods. The purpose of this study was to compare wireless iButtons and hard-wired thermistors for human skin temperature measurement. In the first of two investigations, iButtons and thermistors monitored temperature in a controlled water bath (range: 10-40 degrees C) and were referenced against a certified, mercury thermometer. In the second investigation, eight healthy males completed three randomized trials (ambient temperature = 10 degrees C, 20 degrees C and 30 degrees C) while both devices recorded skin temperature at rest (in low and high wind velocities) and during cycle-ergometry exercise. The results are as follows. Investigation 1: both devices displayed very high validity correlation with the reference thermometer (r > 0.999). Prior to correction, the mean bias was +0.121 degrees C for iButtons and +0.045 degrees C for thermistors. Upon calibration correction the mean bias for iButtons and thermistors was not significantly different from zero bias. Interestingly, a typical error of the estimate of iButtons (0.043 degrees C) was 1.5 times less than that of thermistors (0.062 degrees C), demonstrating iButtons' lower random error. Investigation 2: the offset between iButton and thermistor readings was generally consistent across conditions; however, thermistor responses gave readings that were always closer to ambient temperature than those given by iButtons, suggesting potential thermistor drift towards environmental conditions. Mean temperature differences between iButtons and thermistors during resting trials ranged from 0.261 degrees C to 1.356 degrees C. Mean temperature differences between iButtons and thermistors during exercise were 0.989 degrees C (ambient temperature = 10 degrees C), 0.415 degrees C (ambient temperature = 20 degrees C) and 0.318 degrees C (ambient temperature = 30 degrees C). Observed error estimates were within the acceptable limits for the skin temperature method comparison, with typical errors <0.3 degrees C, correlation coefficients >0.9 and CV <1% under all conditions. These findings indicate that wireless iButtons provide a valid alternative for human skin temperature measurement during laboratory and field investigations particularly when skin temperature measurement using other currently available methods may prove problematic.
More Related Videos
08:50Fabrication and Characterization of a Conformal Skin-like Electronic System for Quantitative, Cutaneous Wound Management
Published on: September 2, 2015
04:54Using a Combination of Indirect Calorimetry, Infrared Thermography, and Blood Glucose Levels to Measure Brown Adipose Tissue Thermogenesis in Humans
Published on: June 2, 2023
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...