Related Experiment Video
Updated: Jun 18, 2026

Zebrafish Larvae as a Model to Evaluate Potential Radiosensitizers or Protectors
Published on: August 25, 2022
Radiation exposure in 212 very low and extremely low birth weight infants
Kathrin Puch-Kapst1, Ralf Juran, Brigitte Stoever
1Clinic of Neonatology Charité Campus Mitte, Charité-Universitätsmedizin Berlin, Berlin, Germany .
Objective:
We determined the frequency and estimated effective radiation dose (E) from conventional diagnostic radiographs for infants who had birth weight of
Methods:
Entrance skin doses were experimentally measured for all standard weight-dependent exposure settings. For each radiograph in the radiologic file, the exposed area on the film was measured manually. Together with clinical data obtained from the Vermont Oxford Network, medical charts, and radiologic files, we estimated E. E values per radiograph and per child were compared with recommended reference values and annual natural background radiation (NBR). We used reference data to estimate the risk for radiation-induced cancers.
Results:
Of 212 VLBW infants, 194 required at least 1 conventional radiograph. Measured entrance skin dose varied between 11.8 and 15.0 microGy. Calculated E received was 16 microsievert (microSv; median) per radiograph and 71.5 microSv (median) per infant for the whole stay. Infants with birth weight
Conclusions:
We found that NICU-treated VLBW infants had low radiation exposure compared with the annual NBR.