Analysis of potential genotoxic impurities in pharmaceuticals by two-dimensional gas chromatography with Deans
Frank David1, Karine Jacq, Pat Sandra
1Research Institute for Chromatography, Pres. Kennedypark 26, 8500, Kortrijk, Belgium. frank.david@richrom.com
Abstract:
The analysis of potential genotoxic impurities (PGIs) in active pharmaceutical ingredients (APIs) is a challenging task. The target limit of detection for a PGI in an API is typically 1 ppm (1 microg/g API). This is about 500 times lower than for classical impurity analysis. Consequently, analytical methods for trace analysis, mostly in combination with MS detection, need to be applied for the qualitative and quantitative determination of these impurities. A two-dimensional capillary GC method is presented that can be used for the determination of some target PGIs. A concentrated solution of the API sample is directly introduced in the GC-MS system, using an apolar column for first-dimension separation. The fraction (heart-cut) containing the PGIs is transferred to a second capillary column, installed in a low-thermal-mass oven (LTM). The LTM focuses the heart-cut(s) and allows independent temperature-programmed analysis with a polar second-dimension column. The API, solvent, and derivatization agents are not introduced in the second column or in the MS detector, avoiding contamination, column degradation, and target analyte peak detection/integration issues. The performance of this set-up is illustrated by the analysis of some Michael-reactive acceptor PGIs and haloalcohols in carbamazepine as test matrix. Excellent reproducibility (<10% RSD) at the low parts per million level and low detection limits (<1 ppm) were obtained.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...