Related Experiment Video
Updated: Jun 18, 2026

Two-Dimensional Visualization and Quantification of Labile, Inorganic Plant Nutrients and Contaminants in Soil
Published on: September 1, 2020
[Application of ICP-MS to detection of mineral elements in double-low and double-high rapeseed]
Juan Zou1, Jian-wei Lu, Fang Chen
1College of Resources and Environment, Huazhong Agricultural University, Wuhan 430070, China. zoujuan@webmail.hzau.edu.cn
Abstract:
The object of the present study was to investigate ten necessary mineral elements in different varieties of rapeseed by ICP-MS. Thirty three samples of double-low (low in both glucosinolates and erucic acid) rapeseed (DLR) and 12 samples of double-high rapeseed (DHR) in the Yangtze River Valley were collected. The results showed that rapeseed contained many kinds of necessary elements, and there was a difference between DLR and DHR The average concentrations of P, K, Ca, Mg, S, Fe, Mn, Cu, Zn and B in DLR were 6.26 mg x g(-1), 10.17 mg x g(-1), 6.75 mg x g(-1), 4.82 mg x g(-1), 4.52 mg x g(-1), 96.20 microg x g(-1), 37.10 microg x g(-1), 3.84 microg x g(-1), 41.61 microg x g(-1) and 12.16 microg x g(-1), respectively, while for the mineral elements in DHR, the average values were 5.97 mg x g(-1), 10. 14 mg x g(-1), 6.31 mg x g(-1), 4.50 mg x g(-1), 9.06 mg x g(-1), 77.03 microg x g(-1), 49.86 microg x g(-1), 3.72 microg x g(-1), 40.58 microg x g(-1) and 11.79 microg x g(-1). The contents of most elements in DLR were higher than those in DHR, such as P, K, Ca, Mg, Fe, Cu, Zn and B. Furthermore, the differences in Ca, Mg and Fe contents between the two varieties were significant. It was concluded that the difference in concentrations of mineral elements can be regarded as a necessary factor for popularizing double-low rapeseed in the Yangtze River Valley.
More Related Videos
09:05Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry (LA-ICP-MS)
Published on: January 22, 2017
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
High-Resolution Mass Spectrometry (HRMS)