Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Influence of different presentations of oscillometric data on automatic determination of systolic and diastolic
Vojko Jazbinsek1, Janko Luznik, Stephan Mieke
1Institute of Mathematics, Physics and Mechanics, University of Ljubljana, Jadranska 19, SI-1000, Ljubljana, Slovenia. vojko.jazbinsek@imfm.uni-lj.si
Abstract:
Most non-invasive blood pressure measurements are based on either the auscultatory or the oscillometric technique. In this study, we performed an extensive analysis of the signals, i.e., responses of a microphone implanted in the cuff and pressure changes in the cuff, which can be recorded during such measurements. We applied several methods to separate the cuff deflation from the arterial pressure pulses, as well as to separate the microphone data into an audible part (Korotkoff sounds) and a low frequency part. The oscillometric technique is based on some empirically derived criteria applied to the oscillometric index, which is defined as a certain characteristic physical property of pressure pulses. In addition to the pressure pulses, which are a typical physical property used for the oscillometric index, we also used in this study other properties such as a time derivative and an audible part of data measured by a microphone implanted in the cuff (Korotkoff sounds). We performed a case study of 23 healthy subjects to evaluate the influence of different presentations of the oscillometric index on known height-based and slope-based empirical algorithms for the automatic determination of the systolic and diastolic blood pressures.
More Related Videos
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure