Drug-Induced Sleep Endoscopy (DISE) with Target Controlled Infusion (TCI) and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
The tongue-retaining device: efficacy and side effects in obstructive sleep apnea syndrome
Diane S Lazard1, Marc Blumen, Pierre Lévy
1Assistance Publique-Hôpitaux de Paris, Hôpital Beaujon, Service d'ORL et de Chirurgie Cervico-Faciale, Clichy, France. diane.lazard@bjn.aphp.fr
Study Objectives:
The tongue-retaining device is a customized monobloc oral appliance used in the treatment of obstructive sleep apnea syndrome (OSAS). This study evaluated tongue-retaining device efficacy and its tolerance by patients with OSAS.
Methods:
The charts of 84 apneic patients were retrospectively analyzed, and patients were contacted by telephone to answer an oral questionnaire. The median follow-up time was 5 years.
Results:
Based on the apnea-hypopnea index, a complete or partial response was obtained in 71% of the cases. The mean apnea-hypopnea index decreased significantly from 38 to 14 (p < 0.001) with the tongue-retaining device. The subjective intensity of snoring decreased by 68% (p < 0.0001) and the Epworth Sleepiness Scale score decreased from 9 to 6 (p < 0.05). An age of more than 60 years associated with a mandibular protrusion distance inferior or equal to 7 mm was predictive of a nonresponse (odds ratio [OR]: 7.25; 95% confidence interval [CI]: 1.43-36.7; p < 0.02). The compliance rate, as determined by answers to the questionnaire, was 52% after 5 years of follow-up. Nasal obstruction was a negative predictor of good compliance (OR: 6.94; 95% CI: 0.28-0.79; p < 0.005), whereas patients with Class I occlusion were more compliant than patients with Class II or III occlusions (OR: 3.83; 95% CI: 1.00-2.81; p < 0.05).
Conclusions:
Tongue-retaining device performance tended to be similar to that of the mandibular advancement device. Thus, teams trained in tongue-retaining device fabrication and fitting may propose it as an alternative to continuous positive airway pressure, taking nasal obstruction into consideration as a contraindication.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...