Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
Development of new quantitative diagnosis machine to evaluate the baroreflex sensitivity of an artery for patients
Tomoyuki Yambe1, Norihiro Sugita, Makoto Yoshizawa
1Tohoku University, 4-1 Seryo-machi, Aoba-ku, Sendai 980-8575, Japan. yambe@idac.tohoku.ac.jp
Abstract:
Text book in all medical school showed that the baroreflex system is one of the most important regulatory systems. When blood pressure increases, heart rate decrease and an artery is dilated with the baroreflex system. By decrease of cardiac output and arterial resistances, blood pressure returns to the normal value. However, there is no diagnostic method, which can measure the sensitivity of a baroreflex system of the artery by the simple methodology. We had challenged invention of the new machine, which could diagnose the sensitivity of the baroreflex system of not only a heart, but also an artery. In this system, the measurement sections are only an electrocardiography (ECG) and peripheral pulse wave. These time series is inputted into a personal computer system, and analyzed quantitatively. Responses of the artery were measured with pulse wave velocity (PWV) calculated from pulse wave transmission time from heart to an artery. In this system, the heart rate change corresponding to the blood-pressure change in time series sequence is observed. Delay time was measured by the cross correlation function. Slope of the blood pressure (BP) change and heart rate (HR) change showed the sensitivity of the baroreflex system of heart. Furthermore, this system can measure the sensitivity of the baroreflex system of an artery. Change of PWV in response to the BP change was observed. We found that significant correlation was observed in the time sequence between BP change and PWV change after delay time calculated from cross correlation. Clinical research was started through allowance of the Ethics Committee. Decreased sensibility in the hypertensive patient's baroreflex system was observed as a result of the clinical research. Furthermore, alteration of the baroreflex sensitivity before and after the drug administration was evaluated. For example, Azelnidipine, Calcium antagonists improved the baroreflex sensitivity of the artery in several cases. This system may be useful f- or the follow up of the hypertensive patients.
More Related Videos
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
06:51Development of an Algorithm to Perform a Comprehensive Study of Autonomic Dysreflexia in Animals with High Spinal Cord Injury Using a Telemetry Device
Published on: July 29, 2016
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: