Attempt of a novel calibration method of pulse oximetry using support vector machines regression
Mitsuhiro Ogawa1, Yasuhiro Yamakoshi, Masamichi Nogawa
1The yu.sys Corporation and the Graduate School of Natural Science & Technology, Kanazawa University, Kamuma, Kanazawa, 920-1192, Japan. m_ogawa@y5.dion.ne.jp
Abstract:
A novel calibration method using support vector machines regression (SVMsR) of pulse oximetry was proposed and attempted. Conventional calibration method of pulse oximetry that based on an optical density ratio of transmitted visible red light and infrared radiation whereas a proposed method here was not based on the optical density ratio directly. In theory, conventional calibrations using the ratio can be considered as a technique for nonlinear problem: nonlinear relation between two optical densities (red and IR) and oxygen saturation could be linearized by the ratio calculation. We thought, that nonlinear problem could be solved by using nonlinear analyses. Among them, the support vector machines regression method that has been studied well in this decade was attempted to be applied for pulse oximetry calibration. As an experiment, two photo plethysmograms (PPGs) by red and IR were measured on five subjects. Simultaneously, oxygen saturation (SpO(2)) level was measured by a commercial pulse oxymeter. SpO(2)) level was controlled by breathing 10% oxygen gas obtaining 98-75% SpO(2) level. Sequentially, feature points of two PPGs were extracted in beat by beat. Convex peaks and concave valleys on waveform and DC levels of PPGs were selected as feature points. Then, nonlinear regression using SVMs were attempted to obtain relationship between SpO2 by meter (regressand) and feature points of PPG (regressor). In result, a regression model was constructed from training data that is three fourths of measured cardiac data by using SVMsR. Finally, the constructed calibration model was evaluated by other one third data (validation data). The root mean squared error for the validation data is 1.90 [SpO(2)) level %] and 89% of validation data fell within +/- 2 % of SpO(2) level by the meter. In conclusion, SVMsR might be applicable on calibration for pulse oximetry.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
06:50O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Calibration Curves: Correlation Coefficient
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: