Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Dysrhythmias V: Evaluating Dysrhythmias01:30

Dysrhythmias V: Evaluating Dysrhythmias

Dysrhythmias, also known as arrhythmias, are disturbances in the heart's rhythm that range from benign to life-threatening. A thorough evaluation is crucial for appropriate management and involves a comprehensive medical history, physical examination, and various diagnostic tests.Medical HistorySymptoms: Collect detailed information on palpitations, dizziness, syncope, chest pain, and fatigue. Note their onset, frequency, and triggers.Previous Cardiac Issues: Document any history of heart...
Cardiopulmonary Resuscitation III: AED Use01:23

Cardiopulmonary Resuscitation III: AED Use

Introduction to AEDAn Automated External Defibrillator (AED) is a portable medical device that analyzes the heart's rhythm and, if necessary, delivers an electrical shock to help the heart re-establish an effective rhythm during sudden cardiac arrest (SCA). SCA occurs when the heart suddenly and unexpectedly stops beating, leading to a loss of blood flow to the brain and other vital organs. In such emergencies, time is of the essence, and using an AED, combined with Cardiopulmonary...
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm01:30

Pulse rhythm

Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Dysrhythmias I: Introduction01:15

Dysrhythmias I: Introduction

Dysrhythmias refers to abnormalities in the heart's rhythm. They result from disruptions in the heart's electrical conduction system, which includes the sinoatrial(SA)node, atrioventricular(AV) node, the bundle of His, bundle branches, and Purkinje fibers.Definition and PathophysiologyDysrhythmias result from disorders of impulse formation, impulse conduction, or both. The heart contains specialized cells in the sinoatrial node, atrioventricular node, and the bundle of His and Purkinje fibers...
Assessment of apical pulse01:17

Assessment of apical pulse

Assessing the Apical Pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same journal

Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025

Related Experiment Video

Updated: Jun 18, 2026

Exercise Test for Evaluation of the Functional Efficacy of the Pig Cardiovascular System
02:47

Exercise Test for Evaluation of the Functional Efficacy of the Pig Cardiovascular System

Published on: May 12, 2023

Defibrillator synchronization tester.

Fatma N Demirbilek, Mike Krajnak, George Stolarczyk

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |December 8, 2009
    PubMed
    Summary

    This study details checking defibrillator sync signals for accurate synchronized cardioversion. A specialized tester simplifies this crucial diagnostic, ensuring patient monitor and defibrillator compatibility.

    More Related Videos

    A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
    16:40

    A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

    Published on: February 28, 2012

    Related Experiment Videos

    Last Updated: Jun 18, 2026

    Exercise Test for Evaluation of the Functional Efficacy of the Pig Cardiovascular System
    02:47

    Exercise Test for Evaluation of the Functional Efficacy of the Pig Cardiovascular System

    Published on: May 12, 2023

    A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
    16:40

    A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation

    Published on: February 28, 2012

    Area of Science:

    • Biomedical Engineering
    • Cardiovascular Technology

    Background:

    • Defibrillator sync output provides ECG signals for synchronized cardioversion, crucial for treating cardiac arrhythmias.
    • Accurate R-wave timing during cardioversion prevents inducing ventricular fibrillation.
    • GE patient monitors offer analog output for ECG or blood pressure, enabling synchronized balloon pumps for cardiac assist.

    Purpose of the Study:

    • To describe the process and importance of checking defibrillator sync output signals.
    • To highlight the role of these signals in synchronized cardioversion and cardiac assist.
    • To introduce a method for verifying defibrillator sync signal functionality.

    Main Methods:

    • Utilizing a GE defibrillator sync tester for signal verification.
    • Implementing a loop-back path for signals to display on the patient monitor.
    • Performing checks during planned maintenance and after significant component replacements.

    Main Results:

    • The defibrillator sync tester allows for direct display of sync signals on the patient monitor.
    • This eliminates the need for external oscilloscopes, simplifying the checkout process.
    • Ensures proper functioning of the defibrillator sync and analog output features.

    Conclusions:

    • Regular checks of defibrillator sync signals are essential for safe and effective synchronized cardioversion.
    • The GE defibrillator sync tester provides an efficient and integrated solution for signal verification.
    • Proper maintenance and testing of these systems are critical for patient safety and device reliability.