Related Experiment Video
Updated: Jun 18, 2026

Patient-specific Modeling of the Heart: Estimation of Ventricular Fiber Orientations
Published on: January 8, 2013
A computer study of the effects of branching dimension on safety factor distribution and propagation in a cardiac
Jichao Zhao1, Bruce H Smaill, Andrew J Pullan
1Bioengineering Institute, The University of Auckland, 1142, New Zealand. j.zhao@auckland.ac.nz
Abstract:
Branching conduction networks are responsible for coordinated distribution of activation throughout the heart, but the effects of branching geometry on the efficiency of distribution and the safety of propagation remain unclear. We have developed a simplified computer model to investigate this issue in a systemic fashion. A simplified 2D model that reproduces key features of the right atrial pectinate muscle network has been developed. This consists of a large main strand that gives rise to regularly spaced perpendicular branches. Safety factor (SF) and activation time (AT) within the network are estimated for a range of different branch dimensions. The SF is reduced as branch dimension is increased due to the larger current load and is least at the proximal edge of the junction between the main strand and branches. On the other hand, activation efficiency depends on appropriate balance between the load imposed by branching and source which they subsequently provide. With repeated stimulation at progressively decreasing coupling intervals, the SF and conduction fall within the network, but the locations of block varied with branching dimension, again reflecting spatial variation in the balance between current source and current load. We hypothesize that the observed geometry of the branching network optimizes distribution efficiency and propagation safety.
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Circuit Terminology
A circuit, on the other hand, is also an interconnected system of electrical elements but must contain one or more closed paths.