Detection of cardiac activity using a 5.8 GHz radio frequency sensor
1The Institute of Electronics, Communications and Information Technology, Queen's University Belfast, Belfast BT3 9DT, Northern Ireland, U.K.
Abstract:
A 5.8-GHz ISM-Band radio-frequency sensor has been developed for non-contact measurement of respiration and heart rate from stationary and semi-stationary subjects at a distance of 0.5 to 1.5 meters. We report on the accuracy of the heart rate measurements obtained using two algorithmic approaches, as compared to a reference heart rate obtained using a pulse oximeter. Simultaneous Photoplethysmograph (PPG) and non-contact sensor recordings were recorded over fifteen minute periods for ten healthy subjects (8M/2F, ages 29.6 + or - 5.6 yrs) One algorithm is based on automated detection of individual peaks associated with each cardiac cycle; a second algorithm extracts a heart rate over a 60-second period using spectral analysis. Peaks were also extracted manually for comparison with the automated method. The peak-detection methods were less accurate than the spectral methods, but suggest the possibility of acquiring beat by beat data; the spectral algorithms measured heart rate to within + or -10% for the ten subjects chosen. Non-contact measurement of heart rate will be useful in chronic disease monitoring for conditions such as heart failure and cardiovascular disease.
More Related Videos
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
08:25Construction of a Wireless-Enabled Endoscopically Implantable Sensor for pH Monitoring with Zero-Bias Schottky Diode-based Receiver
Published on: August 27, 2021
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Holter Monitor: 24-Hour Monitoring
Electrophysiology of Normal Cardiac Rhythm
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...