Multivariate regression and discreminant calibration models for a novel optical non-invasive blood glucose
Yasuhiro Yamakoshi1, Mitsuhiro Ogawa, Takehiro Yamakoshi
1yu.sys Corporation, Kanazawa, Ishikawa, 920-1167, Japan. y@yusys.jp
Abstract:
A novel optical non-invasive in vivo blood glucose concentration (BGL) measurement technique, named "Pulse Glucometry", was combined with a kernel method; support vector machines. The total transmitted radiation intensity (I(lambda)) and the cardiac-related pulsatile changes superimposed on I(lambda) in human adult fingertips were measured over the wavelength range from 900 to 1700 nm using a very fast spectrophotometer, obtaining a differential optical density (DeltaOD(lambda)) related to the blood component in the finger tissues. Subsequently, a calibration model using paired data of a family of DeltaOD(lambda)s and the corresponding known BGLs was constructed with support vector machines (SVMs) regression instead of using calibration by a conventional primary component regression (PCR) and partial least squares regression (PLS). Secondly, SVM method was applied to make a nonlinear discriminant calibration model for "Pulse glucometry." Our results show that the regression calibration model based on the support vector machines can provide a good regression for the 101 paired data, in which the BGLs ranged from 89.0-219 mg/dl (4.94-12.2 mmol/l). The resultant regression was evaluated by the Clarke error grid analysis and all data points fell within the clinically acceptable regions (region A: 93%, region B: 7%). The discriminant calibration model using SVMs also provided a good result for classification (accuracy rate 84% in the best case).
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring pulse
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...