Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Concordance between side-stream end-tidal carbon dioxide and arterial carbon dioxide partial pressure in respiratory
Grace T S Law1, C Y Wong, C W Kwan
1Department of Medicine and Geriatrics, Kwong Wah Hospital, 25 Waterloo Road, Kowloon, Hong Kong.
Objective:
To explore the correlation and concordance between end-tidal carbon dioxide and arterial carbon dioxide partial pressure, and confirm the experience of the general consensus among service environments.
Design:
A prospective cross-sectional analysis.
Setting:
Two respiratory service units in Hong Kong.
Participants:
Two hundred respiratory patients were recruited, in whom 219 sets of observations were recorded. Patients deemed to require arterial blood gas determination also had their end-tidal carbon dioxide partial pressure measured at that time, using two LifeSense LS1-9R Capnometers.
Main Outcome Measures:
The agreement of end-tidal carbon dioxide partial pressure and arterial carbon dioxide partial pressure was studied by correlation coefficients, mean and standard deviation of their difference, and the Bland-Altman plot.
Results:
Overall, the correlation was low and insignificant (r=0.1185, P=0.0801). The mean of the difference was 7.2 torr (95% confidence interval, 5.5-8.9) and significant (P<0.001). The limits of agreement by Bland-Altman analysis were -18.1 to 32.5 torr, which were too large to be acceptable. In the sub-group on room air, the mean difference was reduced to 2.26 torr, the correlation between end-tidal carbon dioxide partial pressure and arterial carbon dioxide partial pressure was 0.2194 (P=0.0068), though statistically significant, the extent of correlation was still low.
Conclusion:
End-tidal carbon dioxide partial pressure did not show significant correlation or concordance with arterial carbon dioxide partial pressure, especially when supplemental oxygen was used. End-tidal carbon dioxide partial pressure currently cannot replace arterial blood gas measurement as a tool for monitoring arterial carbon dioxide partial pressure. Possible reasons for the discrepancy with previous studies include small sample size in previous studies, lack of research facilities in service settings, and publication bias against negative studies.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and HCO3− values are examined to...
Respiratory Regulation of Acid-Base Balance
When carbon dioxide levels increase in the blood, more H+ and HCO3⁻ are produced, leading to a...
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Chemical Factors Affecting Respiration Centers
CO2 has a potent influence on respiration and is strictly regulated. Under...
Acute Respiratory Failure-III