Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Angle Closure Glaucoma: Treatment01:28

Angle Closure Glaucoma: Treatment

1.4K
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.4K
Focusing of Light in the Eye01:16

Focusing of Light in the Eye

6.7K
Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
6.7K
Photoreceptors and Visual Pathways01:22

Photoreceptors and Visual Pathways

9.8K
At the molecular level, visual signals trigger transformations in photopigment molecules, resulting in changes in the photoreceptor cell's membrane potential. The photon's energy level is denoted by its wavelength, with each specific wavelength of visible light associated with a distinct color. The spectral range of visible light, classified as electromagnetic radiation, spans from 380 to 720 nm. Electromagnetic radiation wavelengths exceeding 720 nm fall under the infrared category,...
9.8K
Glaucoma: Overview01:25

Glaucoma: Overview

1.5K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Visual Field Progression in Glaucoma Patients With Delayed Follow-Up.

American journal of ophthalmology·2026
Same author

Clinical Outcomes of a Prosthetic Capsular Bag for Scleral Fixation of an Intraocular Lens in Eyes without Capsular Support.

Ophthalmology·2026
Same author

Open Angle Glaucoma Treatment Preferences of Glaucoma Specialists in the United States.

Journal of glaucoma·2025
Same author

A Call to Action and Roadmap for Improving Emergency Treatment of Ophthalmic Trauma in the United States.

Ophthalmology·2025
Same author

Weather, Air Pollution, and Seasonality: Predictors of Pathogen-Associated Conjunctivitis Outbreaks in Kathmandu Valley, Nepal.

The American journal of tropical medicine and hygiene·2025
Same author

Use of Large Language Models to Classify Epidemiological Characteristics in Synthetic and Real-World Social Media Posts About Conjunctivitis Outbreaks: Infodemiology Study.

Journal of medical Internet research·2025
Same journal

Laser vision correction (LASIK, PRK, SMILE) with simultaneous accelerated corneal crosslinking.

Current opinion in ophthalmology·2026
Same journal

Traumatic macular hole: observe, operate, or other options.

Current opinion in ophthalmology·2026
Same journal

The evolving role of artificial intelligence in ophthalmology: basic science, translation, and clinical integration.

Current opinion in ophthalmology·2026
Same journal

Editorial: reducing risk for refractive surgery.

Current opinion in ophthalmology·2026
Same journal

Updates on Refractive Surgery: Benefits, Risks, and Costs of Modern Treatment Options.

Current opinion in ophthalmology·2026
Same journal

Corneal Allogeneic Intrastromal Ring Segments for keratoconus - recent evidence and the move to customized and custom shaped CAIRS.

Current opinion in ophthalmology·2026
See all related articles

Related Experiment Video

Updated: Mar 1, 2026

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
05:46

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity

Published on: September 20, 2024

850

Cataract surgery after refractive surgery.

Ayman Naseri1, Stephen D McLeod

  • 1Department of Ophthalmology, University of California San Francisco, California 94143, USA.

Current Opinion in Ophthalmology
|December 10, 2009
PubMed
Summary
This summary is machine-generated.

Calculating intraocular lens (IOL) power after refractive surgery remains challenging, especially without prior data. Recent methods focus on improving accuracy using advanced technology like Scheimpflug imaging, though optimal solutions are still under investigation.

More Related Videos

Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery
05:19

Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery

Published on: December 1, 2023

1.7K
Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
04:59

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation

Published on: July 7, 2023

3.1K

Related Experiment Videos

Last Updated: Mar 1, 2026

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
05:46

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity

Published on: September 20, 2024

850
Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery
05:19

Author Spotlight: Unraveling the Molecular Mechanisms in PCO and Fibrosis Following Cataract Surgery

Published on: December 1, 2023

1.7K
Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
04:59

Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation

Published on: July 7, 2023

3.1K

Area of Science:

  • Ophthalmology
  • Refractive Surgery
  • Cataract Surgery

Background:

  • Cataract surgery requires precise intraocular lens (IOL) power calculation.
  • Corneal refractive surgery significantly alters ocular optics, complicating pre-existing IOL calculation methods.
  • Accurate IOL selection is crucial for achieving desired visual outcomes post-cataract extraction.

Purpose of the Study:

  • To review recent advancements in IOL calculation for patients who have undergone prior corneal refractive surgery.
  • To highlight challenges and emerging strategies for IOL power determination in this specific patient cohort.

Main Methods:

  • Review of recent literature and contributions.
  • Analysis of novel approaches for IOL calculation.
  • Evaluation of techniques utilizing Scheimpflug camera systems for corneal power measurement.

Main Results:

  • Several new methods aim for accurate IOL power calculations even without prerefractive surgery data.
  • Scheimpflug camera systems are being used to measure corneal power, addressing a key error source.
  • No single optimal solution has been determined due to limited comparative clinical outcomes data.

Conclusions:

  • IOL selection after corneal refractive surgery remains a complex clinical challenge.
  • Current research emphasizes methods independent of preoperative refractive surgery history.
  • Surgeons often use multiple formulas to guide IOL selection in these complex cases.